News

Case histories old

N2 ORS® Fire Prevention plant delivered for European Archive

Another ISOLCELL Oxygen Reduction System reference At the end of 2018 ISOLCELL delivered another N2 Oxygen Reduction System® in order to protect an Archive for High-Value documents in Europe. Project details: Dimensions of the area to be protected: 70 x 27.5 x 16.5 (L x W x H) Volume of the area to be protected:

Read More »
News

N2 ORS® Protezione Incendi totale

La deplezione di ossigeno  Il Leitmotiv che ha caratterizzato lo sviluppo tecnologico nel settore dell’antincendio è stata una crescente focalizzazione per soluzioni sempre più efficaci mirate alla protezione delle persone e dei beni materiali. Fino ad oggi il “focus” era di rivelare il prima possibile il principio di incendio e di estinguerlo il più celermente

Read More »
News

Soundproofing of the NEW ADOX®

High sound performance optimization The new upgraded ADOX® N2 ORS has been designed in order to reduce drastically the noise level. ONLY < 64 DB certified according to ISO 3744:2010 This amazing result has been achieved thanks to an accurate designing, planning and selection of the best components and high performance sound proof cabinet.

Read More »
News

Oxygen Sensors N2 ORS® SIL-3

Oxygen Sensors N2 ORS® SIL – 3 The safety functions of the Oxygen Reduction fire prevention system oxygen measurements (oxygen sensors), i.e. personnel safety regarding the risk of anoxia, should be in line with the requirements imposed by the SIL certification „Safety Integrity Level“. ISOLCELL is happy to announce that its new designed and developed

Read More »
News

Sweden: Successfull ORS plant replacement

Modular ADOX® N2 ORS®, the clever solution see Modular ADOX® ADOX® Series The Mission: Years ago an Oxygen Reduction System has been installed by one of our competitors. Due to high energy consumption, maintenance arising from the installed Nitrogen Production system (Membrane technology), the Client decided to invest in a more reliable and energy efficient solution:

Read More »
News

NEW ISOLCELL N2 ORS® WebServer

N2 OXYGEN REDUCTION SYSTEM® WebServer Access to the system without being present at site The new ISOLCELL N2 ORS® WebServer designed and developed by ISOLCELL is a control systems dedicated to data collection and remote control, monitoring, diagnostic of the installed Oxygen Reduction Fire Prevention plant. The ISOLCELL N2 ORS® WebServer removes all the restrictions

Read More »
News

How a N2 ORS® plant looks like

ORS fire prevention plant according to the general requirements EN 16750 Standard EN 16750:2017 N2 Oxygen reduction system ® plant Modular ADOX® VPSA technology SIL-3 IEC 61508 , oversizing acc. to EN 16750 and redundancy features Main Control Units (Master + Slave), SIL-3 IEC 61508 Manifold with different valves-positions dedicated to specific virtual area, see Virtual

Read More »
News

ISOLCELL: the brand of Controlled Atmosphere

1958, the year we were born Within the context of the Italian economic revolution, fond of new ways of living and investing, we decided to develop the Controlled Atmosphere technology to storage apples and pears produced in large quantities over our territory, the most important fruit production area in Europe. Since then, our progress evolved

Read More »
News

N2 ORS® at the Safety and Security Asia

We are in Singapore! From 01.-03.10.2019 the Safety and Security Asia (SSA) will take place in Marina Bay Sands, Singapore.     Come and visit us at our booth L09     The organisers of Safety & Security Asia (SSA) 2019 welcome you to the 18th International Safety & Security Technology and Equipment Exhibition that is

Read More »